st: r(1000) error when running xi
From
A Loumiotis <[email protected]>
To
[email protected]
Subject
st: r(1000) error when running xi
Date
Mon, 31 Oct 2011 14:01:39 +0200
Hi,
I get the following error when I run xi:
system limit exceeded - see manual
r(1000);
I modified a bit xi and measured the length of the local orig and
found out that the error occurs when the macro length of orig exceeds
165198. I'm surprised because I'm not using Stata/IC where the macro
limit is 165,200 but I'm using Stata/MP where the macro limit is
1,081,511. Do you know why this is happening?
My version of Stata is the following:
.about
Stata/MP 11.2 for Windows (32-bit)
Born 01 Sep 2011
Copyright 1985-2009 StataCorp LP
Total physical memory: 2097151 KB
Available physical memory: 1726136 KB
Thanks,