Stata’s exact confidence interval for the odds ratio inverts Fisher’s exact test. We might expect the interval and test to agree on statistical significance. But they do not always. Here is an example:


. cci 2 31 136 15532, exact
                                                         Proportion
                 |   Exposed   Unexposed  |      Total     Exposed
-----------------+------------------------+------------------------
           Cases |         2          31  |         33       0.0606
        Controls |       136       15532  |      15668       0.0087
-----------------+------------------------+------------------------
           Total |       138       15563  |      15701       0.0088
                 |                        |
                 |      Point estimate    |    [95% Conf. Interval]
                 |------------------------+------------------------
      Odds ratio |         7.368121       |     .845817    29.44578 (exact)
 Attr. frac. ex. |         .8642802       |   -.1822888    .9660393 (exact)
 Attr. frac. pop |         .0523806       |
                 +-------------------------------------------------
                                  1-sided Fisher's exact P = 0.0339
                                  2-sided Fisher's exact P = 0.0339

The p-value is significant at the 5% level, but the confidence interval is not (it includes the null value of one). The test and interval disagree even though they were derived from the same model.

There is no problem with Stata’s implementation of the test or interval. The problem is the difficulty in two-sided inference from asymmetric sampling distributions. Fisher’s exact test handles the difficulty in one way, the interval in another way.

The test naturally gives a one-sided p-value, and there are at least four different ways to convert it to a two-sided p-value (Agresti 2002, 93). One way, not implemented in Stata, is to double the one-sided p-value; doubling is simple but can result in p-values larger than one.

Stata instead adds the probabilities of all the tables at least as unlikely as the observed table. (For a rigorous statement, see Methods and Formulas of [R] tabulate twoway). In our example, all the “unlikelier” tables are in the same tail as the observed table. The other tail does not contribute to the p-value, so the one-sided and two-sided p-values are equal.

However, the other tail is included in the confidence interval, because the confidence interval inverts two one-sided tests, not a two-sided test (Example 10 of [ST] epitab; Breslow and Day 1980, 128–129). That is why the interval disagrees with the p-value.

The interval and p-value can disagree even though they are both “exact” because it is not the coverage probability and type I error probability that are exact. The coverage probability is not exactly 0.95, and the type I error probability is not exactly 0.05. (The 0.95 is a lower bound, and the 0.05 is an upper bound.) The underlying sampling distribution is discrete, so it is not possible to create a nonrandomized confidence interval with a coverage probability of 0.95 or a nonrandomized test with a type I error probability of 0.05.

References

Agresti, A. 2002.
Categorical Data Analysis. 2nd ed. Hoboken, NJ: Wiley.
Breslow, N. E., and N. E. Day. 1980.
Statistical Methods in Cancer Research: Volume 1—The Analysis of Case–Control Studies. Lyon: IARC.
FAQs
What's new?
Statistics
Data management
Graphics
Programming Stata
Mata
Resources
Internet capabilities
Stata for Windows
Stata for Unix
Stata for Mac
Technical support
Resources & support
FAQs
Technical support
NetCourses
Short courses
Users Group meetings
Statalist
Links
Software updates
Software archives
Customer service
Manuals & supplements
Stata Journal
STB
Stata News
Stata Automation
Plugins

Site overview
Products
Resources & support
Company
Site index

© Copyright 1996–2009 StataCorp LP   |   Terms of use   |   Privacy   |   Contact us   |   Site index